<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Gas detector Archives - (주)엘피엠테크-LPMTECH</title>
	<atom:link href="https://lpmtech.co.kr/faq_category/gas-detector/feed/" rel="self" type="application/rss+xml" />
	<link>https://lpmtech.co.kr/faq_category/gas-detector/</link>
	<description>농축기, 세포배양기, 레귤레이터, 가스혼합기, MFC, 스태틱믹서, 유량계 등 실험장비 및 유체 계측/혼합장비 전문업체</description>
	<lastBuildDate>Tue, 29 Mar 2022 01:29:33 +0000</lastBuildDate>
	<language>ko-KR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.7.4</generator>
	<item>
		<title>가연성 가스검지기의 0~100% LEL은 무엇을 나타내는 건가요?</title>
		<link>https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%97%b0%ec%84%b1-%ea%b0%80%ec%8a%a4%ea%b2%80%ec%a7%80%ea%b8%b0%ec%9d%98-0100-lel%ec%9d%80-%eb%ac%b4%ec%97%87%ec%9d%84-%eb%82%98%ed%83%80%eb%82%b4%eb%8a%94-%ea%b1%b4%ea%b0%80%ec%9a%94/</link>
					<comments>https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%97%b0%ec%84%b1-%ea%b0%80%ec%8a%a4%ea%b2%80%ec%a7%80%ea%b8%b0%ec%9d%98-0100-lel%ec%9d%80-%eb%ac%b4%ec%97%87%ec%9d%84-%eb%82%98%ed%83%80%eb%82%b4%eb%8a%94-%ea%b1%b4%ea%b0%80%ec%9a%94/#respond</comments>
		
		<dc:creator><![CDATA[lpm]]></dc:creator>
		<pubDate>Tue, 29 Mar 2022 01:29:33 +0000</pubDate>
				<guid isPermaLink="false">https://lpmtech.co.kr/?post_type=avada_faq&#038;p=20762</guid>

					<description><![CDATA[<p>  가스 폭발은 가스 누설이 발생하여 어느 수준 이상의 농도에 도달하면 발생합니다. 가스 폭발이 시작되는 가스 농도 하한계를 LEL(Lower Explsion Limit) 이라고 합니다. 가스 종류에 따라 LEL 치는 달라지며, 가스검지기는 기본적으로 LEL의 1/4의 값에서 검지하도록 세팅되어 있습니다.</p>
<p>The post <a href="https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%97%b0%ec%84%b1-%ea%b0%80%ec%8a%a4%ea%b2%80%ec%a7%80%ea%b8%b0%ec%9d%98-0100-lel%ec%9d%80-%eb%ac%b4%ec%97%87%ec%9d%84-%eb%82%98%ed%83%80%eb%82%b4%eb%8a%94-%ea%b1%b4%ea%b0%80%ec%9a%94/">가연성 가스검지기의 0~100% LEL은 무엇을 나타내는 건가요?</a> appeared first on <a href="https://lpmtech.co.kr">(주)엘피엠테크-LPMTECH</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p><p id="SE-357e5709-e403-4d8d-82b0-8540adf3ac66" class="se-text-paragraph se-text-paragraph-align-center " style="text-align: center;"><span id="SE-db4985ad-d8c5-4707-abe0-1d8a991de05a" class="se-fs-fs16 se-ff-nanumsquare   " style="color: #000000;">가스 폭발은 가스 누설이 발생하여 어느 수준 이상의 농도에 도달하면 발생합니다.</span></p><p id="SE-ac6a8011-5238-47ba-bc18-ade895f4c60d" class="se-text-paragraph se-text-paragraph-align-center " style="text-align: center;"><span id="SE-999bd1c1-ab69-4686-a3d4-de3a64d5d52d" class="se-fs-fs16 se-ff-nanumsquare   " style="color: #000000;">가스 폭발이 시작되는 가스 농도 하한계를 LEL(Lower Explsion Limit) 이라고 합니다.</span></p><p id="SE-c070b2e4-a9c5-4851-8fd4-881868f37769" class="se-text-paragraph se-text-paragraph-align-center " style="text-align: center;"><span id="SE-6735f091-a63b-4baa-83ea-b63bda424453" class="se-fs-fs16 se-ff-nanumsquare   " style="color: #000000;">가스 종류에 따라 LEL 치는 달라지며, 가스검지기는 기본적으로 LEL의 1/4의 값에서 검지하도록 세팅되어 있습니다.</span></p><p>The post <a href="https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%97%b0%ec%84%b1-%ea%b0%80%ec%8a%a4%ea%b2%80%ec%a7%80%ea%b8%b0%ec%9d%98-0100-lel%ec%9d%80-%eb%ac%b4%ec%97%87%ec%9d%84-%eb%82%98%ed%83%80%eb%82%b4%eb%8a%94-%ea%b1%b4%ea%b0%80%ec%9a%94/">가연성 가스검지기의 0~100% LEL은 무엇을 나타내는 건가요?</a> appeared first on <a href="https://lpmtech.co.kr">(주)엘피엠테크-LPMTECH</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%97%b0%ec%84%b1-%ea%b0%80%ec%8a%a4%ea%b2%80%ec%a7%80%ea%b8%b0%ec%9d%98-0100-lel%ec%9d%80-%eb%ac%b4%ec%97%87%ec%9d%84-%eb%82%98%ed%83%80%eb%82%b4%eb%8a%94-%ea%b1%b4%ea%b0%80%ec%9a%94/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>가스검지기와 수신반 연결 시, 신호선은 어떤 종류를 사용하는 것이 좋은가요?</title>
		<link>https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%8a%a4%ea%b2%80%ec%a7%80%ea%b8%b0%ec%99%80-%ec%88%98%ec%8b%a0%eb%b0%98-%ec%97%b0%ea%b2%b0-%ec%8b%9c-%ec%8b%a0%ed%98%b8%ec%84%a0%ec%9d%80-%ec%96%b4%eb%96%a4-%ec%a2%85%eb%a5%98%eb%a5%bc/</link>
					<comments>https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%8a%a4%ea%b2%80%ec%a7%80%ea%b8%b0%ec%99%80-%ec%88%98%ec%8b%a0%eb%b0%98-%ec%97%b0%ea%b2%b0-%ec%8b%9c-%ec%8b%a0%ed%98%b8%ec%84%a0%ec%9d%80-%ec%96%b4%eb%96%a4-%ec%a2%85%eb%a5%98%eb%a5%bc/#respond</comments>
		
		<dc:creator><![CDATA[lpm]]></dc:creator>
		<pubDate>Fri, 07 Jan 2022 04:49:28 +0000</pubDate>
				<guid isPermaLink="false">https://lpmtech.co.kr/?post_type=avada_faq&#038;p=20647</guid>

					<description><![CDATA[<p>  기본적으로 권장드리는 신호선은 0.75 squere 이상의 shield 선 사용하는 것을 권장드립니다.    </p>
<p>The post <a href="https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%8a%a4%ea%b2%80%ec%a7%80%ea%b8%b0%ec%99%80-%ec%88%98%ec%8b%a0%eb%b0%98-%ec%97%b0%ea%b2%b0-%ec%8b%9c-%ec%8b%a0%ed%98%b8%ec%84%a0%ec%9d%80-%ec%96%b4%eb%96%a4-%ec%a2%85%eb%a5%98%eb%a5%bc/">가스검지기와 수신반 연결 시, 신호선은 어떤 종류를 사용하는 것이 좋은가요?</a> appeared first on <a href="https://lpmtech.co.kr">(주)엘피엠테크-LPMTECH</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"> </p><p style="text-align: center;"><span style="color: #000000;">기본적으로 권장드리는 신호선은 0.75 squere 이상의 shield 선 사용하는 것을 권장드립니다.</span></p><p>&nbsp;</p><p>&nbsp;</p><p>The post <a href="https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%8a%a4%ea%b2%80%ec%a7%80%ea%b8%b0%ec%99%80-%ec%88%98%ec%8b%a0%eb%b0%98-%ec%97%b0%ea%b2%b0-%ec%8b%9c-%ec%8b%a0%ed%98%b8%ec%84%a0%ec%9d%80-%ec%96%b4%eb%96%a4-%ec%a2%85%eb%a5%98%eb%a5%bc/">가스검지기와 수신반 연결 시, 신호선은 어떤 종류를 사용하는 것이 좋은가요?</a> appeared first on <a href="https://lpmtech.co.kr">(주)엘피엠테크-LPMTECH</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%8a%a4%ea%b2%80%ec%a7%80%ea%b8%b0%ec%99%80-%ec%88%98%ec%8b%a0%eb%b0%98-%ec%97%b0%ea%b2%b0-%ec%8b%9c-%ec%8b%a0%ed%98%b8%ec%84%a0%ec%9d%80-%ec%96%b4%eb%96%a4-%ec%a2%85%eb%a5%98%eb%a5%bc/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>정전 시에도 비상전력으로 30분 이상 작동 가능할까요?</title>
		<link>https://lpmtech.co.kr/faq-items/%ec%a0%95%ec%a0%84-%ec%8b%9c%ec%97%90%eb%8f%84-%eb%b9%84%ec%83%81%ec%a0%84%eb%a0%a5%ec%9c%bc%eb%a1%9c-30%eb%b6%84-%ec%9d%b4%ec%83%81-%ec%9e%91%eb%8f%99-%ea%b0%80%eb%8a%a5%ed%95%a0%ea%b9%8c%ec%9a%94/</link>
					<comments>https://lpmtech.co.kr/faq-items/%ec%a0%95%ec%a0%84-%ec%8b%9c%ec%97%90%eb%8f%84-%eb%b9%84%ec%83%81%ec%a0%84%eb%a0%a5%ec%9c%bc%eb%a1%9c-30%eb%b6%84-%ec%9d%b4%ec%83%81-%ec%9e%91%eb%8f%99-%ea%b0%80%eb%8a%a5%ed%95%a0%ea%b9%8c%ec%9a%94/#respond</comments>
		
		<dc:creator><![CDATA[lpm]]></dc:creator>
		<pubDate>Fri, 07 Jan 2022 04:45:11 +0000</pubDate>
				<guid isPermaLink="false">https://lpmtech.co.kr/?post_type=avada_faq&#038;p=20645</guid>

					<description><![CDATA[<p>  수신반 1채널 기준 180분 사용 가능한 백업 배터리가 내장되어 있으며, 최대 5채널까지는 기본 백업 배터리로 30분 동작이 가능합니다. ​ 채널 수가 증가할 경우 담당자와 협의하여 백업 배터리를 추가로 장착할 수 있으며, 현장 상황에 맞춰 UPS까지 추가 설치할 수 있습니다.    </p>
<p>The post <a href="https://lpmtech.co.kr/faq-items/%ec%a0%95%ec%a0%84-%ec%8b%9c%ec%97%90%eb%8f%84-%eb%b9%84%ec%83%81%ec%a0%84%eb%a0%a5%ec%9c%bc%eb%a1%9c-30%eb%b6%84-%ec%9d%b4%ec%83%81-%ec%9e%91%eb%8f%99-%ea%b0%80%eb%8a%a5%ed%95%a0%ea%b9%8c%ec%9a%94/">정전 시에도 비상전력으로 30분 이상 작동 가능할까요?</a> appeared first on <a href="https://lpmtech.co.kr">(주)엘피엠테크-LPMTECH</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p style="text-align: center;"> </p><p id="SE-71b20fec-68ec-49e1-a0b8-4c9a9fbae6f5" class="se-text-paragraph se-text-paragraph-align-center " style="text-align: center;"><span id="SE-4088bb0b-5884-4e71-8626-d7a6c635d31c" class="se-fs-fs16 se-ff-nanumsquare   ">수신반 1채널 기준 180분 사용 가능한 백업 배터리가 내장되어 있으며, </span></p><p id="SE-9478a77b-2837-4e6d-ac9a-bea20266558d" class="se-text-paragraph se-text-paragraph-align-center " style="text-align: center;"><span id="SE-44b3d1e5-4c4c-45c4-bc87-790940411dea" class="se-fs-fs16 se-ff-nanumsquare   ">최대 5채널까지는 기본 백업 배터리로 30분 동작이 가능합니다.</span></p><p id="SE-1d9086b0-822e-4ed0-812a-a45ef312dd0b" class="se-text-paragraph se-text-paragraph-align-center " style="text-align: center;"><span id="SE-2dfb5d8e-cd42-4830-a0cb-2b9a8eda84f0" class="se-fs-fs16 se-ff-nanumsquare   ">​</span></p><p id="SE-95063857-f611-4086-aa61-23cd7dac1a54" class="se-text-paragraph se-text-paragraph-align-center " style="text-align: center;"><span id="SE-a29f76da-eaa6-4613-8c7a-76a1a34d32d6" class="se-fs-fs16 se-ff-nanumsquare   ">채널 수가 증가할 경우 담당자와 협의하여 백업 배터리를 추가로 장착할 수 있으며, </span></p><p class="se-text-paragraph se-text-paragraph-align-center " style="text-align: center;"><span class="se-fs-fs16 se-ff-nanumsquare   ">현장 상황에 맞춰 UPS까지 추가 설치할 수 있습니다.</span></p><p>&nbsp;</p><p style="text-align: center;"> </p><p>The post <a href="https://lpmtech.co.kr/faq-items/%ec%a0%95%ec%a0%84-%ec%8b%9c%ec%97%90%eb%8f%84-%eb%b9%84%ec%83%81%ec%a0%84%eb%a0%a5%ec%9c%bc%eb%a1%9c-30%eb%b6%84-%ec%9d%b4%ec%83%81-%ec%9e%91%eb%8f%99-%ea%b0%80%eb%8a%a5%ed%95%a0%ea%b9%8c%ec%9a%94/">정전 시에도 비상전력으로 30분 이상 작동 가능할까요?</a> appeared first on <a href="https://lpmtech.co.kr">(주)엘피엠테크-LPMTECH</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://lpmtech.co.kr/faq-items/%ec%a0%95%ec%a0%84-%ec%8b%9c%ec%97%90%eb%8f%84-%eb%b9%84%ec%83%81%ec%a0%84%eb%a0%a5%ec%9c%bc%eb%a1%9c-30%eb%b6%84-%ec%9d%b4%ec%83%81-%ec%9e%91%eb%8f%99-%ea%b0%80%eb%8a%a5%ed%95%a0%ea%b9%8c%ec%9a%94/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>가연성 가스 및 산소 검지기의 센서 교체주기는 어떻게 되나요?</title>
		<link>https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%97%b0%ec%84%b1-%ea%b0%80%ec%8a%a4-%eb%b0%8f-%ec%82%b0%ec%86%8c-%ea%b2%80%ec%a7%80%ea%b8%b0%ec%9d%98-%ec%84%bc%ec%84%9c-%ea%b5%90%ec%b2%b4%ec%a3%bc%ea%b8%b0%eb%8a%94-%ec%96%b4%eb%96%bb/</link>
					<comments>https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%97%b0%ec%84%b1-%ea%b0%80%ec%8a%a4-%eb%b0%8f-%ec%82%b0%ec%86%8c-%ea%b2%80%ec%a7%80%ea%b8%b0%ec%9d%98-%ec%84%bc%ec%84%9c-%ea%b5%90%ec%b2%b4%ec%a3%bc%ea%b8%b0%eb%8a%94-%ec%96%b4%eb%96%bb/#respond</comments>
		
		<dc:creator><![CDATA[lpm]]></dc:creator>
		<pubDate>Fri, 07 Jan 2022 04:36:39 +0000</pubDate>
				<guid isPermaLink="false">https://lpmtech.co.kr/?post_type=avada_faq&#038;p=20638</guid>

					<description><![CDATA[<p>    ↑ (좌) 정상 센서 / (우) 부식된 센서     가스검지기 센서 교체주기는 보편적으로 12개월 ~ 48개월 정도이며, 센싱 방식 및 설치환경에 따라 사용 수명이 가감됩니다. ​ 상기 사진은 습도가 높은 곳에 설치된 산소 검지기 센서 (전기화학식)의 부식 사례입니다. (오른쪽 - 사용기간 1년 미만) 센서 교체주기 관련 자세한 사항은 담당자와 상담 바랍니다.    [...]</p>
<p>The post <a href="https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%97%b0%ec%84%b1-%ea%b0%80%ec%8a%a4-%eb%b0%8f-%ec%82%b0%ec%86%8c-%ea%b2%80%ec%a7%80%ea%b8%b0%ec%9d%98-%ec%84%bc%ec%84%9c-%ea%b5%90%ec%b2%b4%ec%a3%bc%ea%b8%b0%eb%8a%94-%ec%96%b4%eb%96%bb/">가연성 가스 및 산소 검지기의 센서 교체주기는 어떻게 되나요?</a> appeared first on <a href="https://lpmtech.co.kr">(주)엘피엠테크-LPMTECH</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p><p>&nbsp;</p><p><span style="color: #000000;"><img fetchpriority="high" decoding="async" class="alignnone size-large wp-image-20639 aligncenter" src="https://lpmtech.co.kr/wp-content/uploads/2022/01/엘피엠_가스검지기-센서-1024x428.gif" alt="" width="1024" height="428" srcset="https://lpmtech.co.kr/wp-content/uploads/2022/01/엘피엠_가스검지기-센서-200x84.gif 200w, https://lpmtech.co.kr/wp-content/uploads/2022/01/엘피엠_가스검지기-센서-300x125.gif 300w, https://lpmtech.co.kr/wp-content/uploads/2022/01/엘피엠_가스검지기-센서-400x167.gif 400w, https://lpmtech.co.kr/wp-content/uploads/2022/01/엘피엠_가스검지기-센서-600x251.gif 600w, https://lpmtech.co.kr/wp-content/uploads/2022/01/엘피엠_가스검지기-센서-768x321.gif 768w, https://lpmtech.co.kr/wp-content/uploads/2022/01/엘피엠_가스검지기-센서-800x334.gif 800w, https://lpmtech.co.kr/wp-content/uploads/2022/01/엘피엠_가스검지기-센서-1024x428.gif 1024w, https://lpmtech.co.kr/wp-content/uploads/2022/01/엘피엠_가스검지기-센서-1200x501.gif 1200w" sizes="(max-width: 1024px) 100vw, 1024px" /></span></p><p style="text-align: center;"><span style="color: #000000;">↑ (좌) 정상 센서 / (우) 부식된 센서</span></p><p>&nbsp;</p><p>&nbsp;</p><p id="SE-0821c836-8641-4907-b977-cd50ac408bb4" class="se-text-paragraph se-text-paragraph-align-center " style="text-align: center;"><span id="SE-00ccbd0a-27ea-4c8f-bf4c-f23cd17bbf87" class="se-fs-fs16 se-ff-nanumsquare   " style="color: #000000;">가스검지기 센서 교체주기는 보편적으로 12개월 ~ 48개월 정도이며, 센싱 방식 및 설치환경에 따라 사용 수명이 가감됩니다.</span></p><p id="SE-e460ccd0-0f9d-40f7-a765-1f6a7039c7f3" class="se-text-paragraph se-text-paragraph-align-center " style="text-align: center;"><span id="SE-60b42972-cb0c-4b68-86e8-2b0706f230ab" class="se-fs-fs16 se-ff-nanumsquare   " style="color: #000000;">​</span></p><p id="SE-7c44c934-e496-4c7d-835e-5a9bb2f3970b" class="se-text-paragraph se-text-paragraph-align-center " style="text-align: center;"><span id="SE-99e6a66e-577a-48d2-b3af-3c783eafa6f1" class="se-fs-fs16 se-ff-nanumsquare   " style="color: #000000;">상기 사진은 습도가 높은 곳에 설치된 산소 검지기 센서 (전기화학식)의 부식 사례입니다. (오른쪽 &#8211; 사용기간 1년 미만)</span></p><p id="SE-68f14378-056e-4a1c-891b-f1627ec0f489" class="se-text-paragraph se-text-paragraph-align-center " style="text-align: center;"><span id="SE-97bfe5ee-cdcc-49b9-a8db-f31c2da790c5" class="se-fs-fs16 se-ff-nanumsquare   " style="color: #000000;">센서 교체주기 관련 자세한 사항은 담당자와 상담 바랍니다.</span></p><p>&nbsp;</p><p>&nbsp;</p><p>The post <a href="https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%97%b0%ec%84%b1-%ea%b0%80%ec%8a%a4-%eb%b0%8f-%ec%82%b0%ec%86%8c-%ea%b2%80%ec%a7%80%ea%b8%b0%ec%9d%98-%ec%84%bc%ec%84%9c-%ea%b5%90%ec%b2%b4%ec%a3%bc%ea%b8%b0%eb%8a%94-%ec%96%b4%eb%96%bb/">가연성 가스 및 산소 검지기의 센서 교체주기는 어떻게 되나요?</a> appeared first on <a href="https://lpmtech.co.kr">(주)엘피엠테크-LPMTECH</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%97%b0%ec%84%b1-%ea%b0%80%ec%8a%a4-%eb%b0%8f-%ec%82%b0%ec%86%8c-%ea%b2%80%ec%a7%80%ea%b8%b0%ec%9d%98-%ec%84%bc%ec%84%9c-%ea%b5%90%ec%b2%b4%ec%a3%bc%ea%b8%b0%eb%8a%94-%ec%96%b4%eb%96%bb/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>가스누출경보 및 자동차단장치 설치장소 및 설치개수</title>
		<link>https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%8a%a4%eb%88%84%ec%b6%9c%ea%b2%bd%eb%b3%b4-%eb%b0%8f-%ec%9e%90%eb%8f%99%ec%b0%a8%eb%8b%a8%ec%9e%a5%ec%b9%98-%ec%84%a4%ec%b9%98%ec%9e%a5%ec%86%8c-%eb%b0%8f-%ec%84%a4%ec%b9%98%ea%b0%9c/</link>
					<comments>https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%8a%a4%eb%88%84%ec%b6%9c%ea%b2%bd%eb%b3%b4-%eb%b0%8f-%ec%9e%90%eb%8f%99%ec%b0%a8%eb%8b%a8%ec%9e%a5%ec%b9%98-%ec%84%a4%ec%b9%98%ec%9e%a5%ec%86%8c-%eb%b0%8f-%ec%84%a4%ec%b9%98%ea%b0%9c/#respond</comments>
		
		<dc:creator><![CDATA[lpm]]></dc:creator>
		<pubDate>Wed, 08 Dec 2021 06:53:24 +0000</pubDate>
				<guid isPermaLink="false">https://lpmtech.co.kr/?post_type=avada_faq&#038;p=20607</guid>

					<description><![CDATA[<p>      검지 경보장치의 설치장소 및 검지경보장치 검출부의 설치 개수는 다음 기준에 따른다. (출처 : 가스안전공사)     2.6.2.3.1 제조시설 &lt;개정 20.3.18&gt; (1) 건축물 안에 설치되어 있는 압축기, 펌프, 반응설비, 저장탱크[(7)에 적은 것을 제외한다] 등 가스가 누출하기 쉬운 고압가스설비 등[(3) 및 (4)에 적은 것을 제외한다]이 설치되어 있는 장소의 주위에는 누출된 가스가 체류하기 쉬운 곳에  [...]</p>
<p>The post <a href="https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%8a%a4%eb%88%84%ec%b6%9c%ea%b2%bd%eb%b3%b4-%eb%b0%8f-%ec%9e%90%eb%8f%99%ec%b0%a8%eb%8b%a8%ec%9e%a5%ec%b9%98-%ec%84%a4%ec%b9%98%ec%9e%a5%ec%86%8c-%eb%b0%8f-%ec%84%a4%ec%b9%98%ea%b0%9c/">가스누출경보 및 자동차단장치 설치장소 및 설치개수</a> appeared first on <a href="https://lpmtech.co.kr">(주)엘피엠테크-LPMTECH</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p><p>&nbsp;</p><p>&nbsp;</p><p style="text-align: center;">검지 경보장치의 설치장소 및 검지경보장치 검출부의 설치 개수는 다음 기준에 따른다.</p><p style="text-align: center;">(출처 : 가스안전공사)</p><p>&nbsp;</p><p style="text-align: left;"> </p><p style="text-align: left;">2.6.2.3.1 제조시설 &lt;개정 20.3.18&gt;</p><p style="text-align: left;">(1) 건축물 안에 설치되어 있는 압축기, 펌프, 반응설비, 저장탱크[(7)에 적은 것을 제외한다] 등 가스가 누출하기 쉬운 고압가스설비 등[(3) 및 (4)에 적은 것을 제외한다]이 설치되어 있는 장소의 주위에는 누출된 가스가 체류하기 쉬운 곳에 이들 설비군의 바닥면 둘레 10m에 대하여 1개 이상의 비율로 계산한 수&lt;개정 20.3.18&gt;</p><p style="text-align: left;">​</p><p style="text-align: left;">(2) 건축물밖에 설치되어 있는 (1)에 적은 고압가스설비가 다른 고압가스설비, 벽이나 그 밖의 구조물에 인접하여 설치된 경우, 피트 등의 내부에 설치되어 있는 경우 및 누출된 가스가 체류할 우려가 있는 장소에 설치되어 있는 경우에는 누출된 가스가 체류할 우려가 있는 장소에 그 설비 군의 바닥면 둘레 20m마다 1개 이상의 비율로 계산한 수, 다만 (7)에 적은 것은 제외한다 &lt;개정 20.3.18&gt;</p><p style="text-align: left;">​</p><p style="text-align: left;">(3) 특수 반응설비[규칙 제8조 별표 4 제1호가목6)아)에서 정한 설비]가 누출된 가스가 체류하기 쉬운 장소에 설치되는 경우에는 그 장소 바닥면 둘레 10m마다 1개 이상의 비율로 계산한 수 &lt;개정 20.3.18&gt;</p><p style="text-align: left;">​</p><p style="text-align: left;">(4) 가열로 등 발화원이 있는 제조설비가 누출된 가스가 체류하기 쉬운 장소에 설치되는 경우에는 그 장소의 바닥면 둘레 20m마다 1개 이상의 비율로 계산한 수 &lt;개정 20.3.18&gt;</p><p style="text-align: left;">​</p><p style="text-align: left;">(5) 계기실 내부에는 1개 이상</p><p style="text-align: left;">​</p><p style="text-align: left;">(6) 독성가스의 충전용 접속구 군의 주위에는 1개 이상</p><p style="text-align: left;">​</p><p style="text-align: left;">(7) 방류둑 (2기 이상의 저장탱크를 집합방류둑 안에 설치한 경우에는 저장탱크 칸막이를 설치한 경우에 한정한다) 안에 설치된 저장탱크의 경우에는 해당 저장탱크마다 1개 이상</p><p style="text-align: left;">​</p><p style="text-align: left;">(8) (1)에 따른 고압가스설비등이 2층 이상의 구조물 위에 설치되어 있는 경우로서 그 바닥이 누출되어 가스가 체류하기 쉬운 구조인 경우에는 그 설비군에 대하여 각 층별로 (1) 및 (2)에서 정하는 비율로 계산한 수 &lt;신설 20.3.18&gt;</p><p style="text-align: left;">​</p><p>The post <a href="https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%8a%a4%eb%88%84%ec%b6%9c%ea%b2%bd%eb%b3%b4-%eb%b0%8f-%ec%9e%90%eb%8f%99%ec%b0%a8%eb%8b%a8%ec%9e%a5%ec%b9%98-%ec%84%a4%ec%b9%98%ec%9e%a5%ec%86%8c-%eb%b0%8f-%ec%84%a4%ec%b9%98%ea%b0%9c/">가스누출경보 및 자동차단장치 설치장소 및 설치개수</a> appeared first on <a href="https://lpmtech.co.kr">(주)엘피엠테크-LPMTECH</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://lpmtech.co.kr/faq-items/%ea%b0%80%ec%8a%a4%eb%88%84%ec%b6%9c%ea%b2%bd%eb%b3%b4-%eb%b0%8f-%ec%9e%90%eb%8f%99%ec%b0%a8%eb%8b%a8%ec%9e%a5%ec%b9%98-%ec%84%a4%ec%b9%98%ec%9e%a5%ec%86%8c-%eb%b0%8f-%ec%84%a4%ec%b9%98%ea%b0%9c/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>