EX-Proof Mass Flow Controllers for gases
EX-FLOW
» Range : lowest range 0.16…8ml/min
up to highest range 7.5…375m3/h
» Accuracy : ±1% of rate
» Connections : compression type or face seal couplings
wafer type on series F-106
DIN or ANSI flanges on series F-107
» Operating pressure : max. 400 bar
» Output signal : 15…20mA
EX-FLOW는 견고한 디자인의 Mass Flow Controller로 가스 유량 (공기 환산)을 측정하고 제어하기 위하여 제어 밸브 통합 또는 별도로 장착할 수 있습니다.
특징
» ATEX 승인 Cat.2, Zone1
» 최대 400bar의 압력 등급
» 견고한 내후성 하우징 (IP65, 먼지 및 방수)
EX-FLOW MFC 시리즈
PN 64 bar |
PN 100 bar | PN 400 bar |
F-200CX / 9.5 … 9.5 ml/min |
F-210CX / 9.5 … 9.5 ml/min |
F-230MX / 10 … 500 ml/min |
F-201CX / 0.015 … 20 l/min |
F-211CX / 0.015 … 20 l/min | F-231MX / 0.5 … 10 l/min |
F-201AX / 5 … 100 l/min | F-211AX / 5 … 100 l/min |
F-231MX / 0.5 … 10 l/min |
F-202AX / 30 … 250 l/min | F-212AX / 30 … 250 l/min |
F-232MX / 10 … 100 l/min |
F-203AX / 200 … 1250 l/min |
F-213AX / 200 … 1250 l/min | |
F-206AX / 20 … 200 m3/h | F-216AX / 20 … 200 m3/h |
|
F-206BX / 50 … 375 m3/h |
F-216BX / 50 … 375 m3/h |
|
적용분야
» Process gas measurement or control in (petro-) chemical industries
» Fuel cell technology
» Gas distribution systems
» Hydrogenation processes
»Gas consumption measurement for internal accounting
»Heating or bio gas production
Measurement / Control System
Accuracy (incl. linearity) |
standard: ±1% FS; |
Turndown |
1 : 50 (2 … 100%) |
Repeatability |
< ±0.2% Rd |
Time constant |
5 seconds |
Operating temperature |
EX-FLOW sensor: -10…+70°C; |
Temperature sensitivity |
zero: < ±0.05% FS/°C; |
Leak integrity |
tested < 2 x 10-9 mbar l/s He |
Attitude sensitivity |
max. error at 90° off horizontal 0.2% |
Machanical parts
Material (wetted parts) |
stainless steel 316L or comparable |
Process connections |
compression type or face seal couplings; |
Seals |
standard: Viton® |
Ingress protection (housing) |
IP65 |
Electrical properties
Signal circuit |
type of explosion protection: intrinsic safety Ex ib IIC, only for connection to a certified intrinsically safe circuit with the following maximum values: |
Output signal |
15…20 mA (linear) |
XB-coil |
Coil voltage max. 28 V/110mA; |
XC-coil |
Coil voltage max. 24 V; |
Models and flow ranges (based on Air) ; PN64 / PN100
Model |
min. flow | max. flow |
F-200CX/F-210CX | 0.2…10 ml/min |
0.2…10 ml/min |
F-201CX/F-211CX |
0.22…11 ml/min | 0.4…20 l/min |
F-201AX/F-211AX | 0.1…5 l/min |
2…100 l/min |
F-202AX/F-212AX |
0.2…10 l/min | 5…250 l/min |
F-203AX/F-213AX | 2…100 l/min |
25…1250 l/min |
F-206AX/F-216AX |
0.4…20 m3/h | 4…200 m3/h |
F-206BX/F-216BX | 1…50 m3/h |
10…500 m3/h |
MFCs for high-pressure / high-ΔP applications ; PN400
Model |
min. flow | max. flow |
F-230MX | 0.2…10 ml/min |
10…500 ml/min |
F-231MX |
10…500 ml/min | 0.2…10 l/min |
F-232MX | 0.2…10 l/min |
2…100 l/min |
* 더 자세한 사양은 카달로그를 참고해주시기 바랍니다.